ROS-8600 Touch color screen RO control system

Character & Application The ROC-860 touch color screen RO control system is a multi function controller with combination of resistance- type touch screen + PLC program control and inline conductivity measuring,it is designed for the system control and water quality testing of reverse osmosis system. The display content of the interface are mainly: Conductivity value monitoring interface, system input signal monitoring,output state display, dynamic system process chart,manual controlling interface, setting interface etc. follow the process state of system in real time, which making people could completely control the whole system very easy. The instrument is available in two versions, single stage control system and double stage control system, the RO controller could monitor the conductivity of raw water, first stage production water, second water production water at same time. With 4-20mA output and RS232 communication system (RS232 adopt MDBUS RTU communication agreement), making the communication between instrument and computer, PLC remote communication and internet. The RO control system making the complete system realize automatic control and unattended monitoring. It could be widely used for pure water equipment,seawater desalination, reverse osmosis system in many industries. Main Technique Specifications
Function Model ROS-8600
Measurement Range Raw water conductivity: 0~20mS/cm, 0~2000μS/cm, One stage RO conductivity: 0~200μS/cm (1.0cm-1 electrode),  Two stage RO conductivity: 0~20μS/cm (1.0cm-1 electrode), Temperature:  0~60℃
Load capacity of relay output connection 5A/250V AC  3A/24V DC;
Power supply External power  DC24V+/-2V/1A
Electrode 1.0cm-1
Control output 10 way relay control output, 1 way switch 4-20mA output
Working pressure of conductance 0~0.5Mpa
Media temperature 0~50℃
Temperature compensation Automatic digital compensation with 25℃ as reference temperature
Measuring distance Not more than 30m
Accuracy 1.5 level
Communication interface RS232(Standard MDBUS communication agreement)
Power ≤ 3KW
Working environment Ambient Temp. 0~50℃, Relative Humidity ≤85%
Dimensions 163mm×226.5mmx 80mm(H X W X D)
Hole size 152×215mm (H X W)
Installation Panel mounted
ⅡTechnical data Singe stage reverse osmosis system ①Collection point of input signal Water level of raw water tank, for checking with or without water Low pressure switch of first stage High pressure switch of first stage Water level switch of pure water tank Hand or automatic control ②Controlling point of output Raw water pump High pressure pump of first stage High pressure pump of second stage Inlet valve Pretreatment valve Flushing valve Over-limit discharge valve of first stage conductivity Over-limit discharge valve of second stage ③ Measure collection point Raw water conductivity collection, Pure water conductivity collection, Temperature collection ④Measuring Range Raw water conductivity: 0~2000μS/cm; Pure water RO conductivity: 0~200μS/cm, Temperature test: 0-60℃ Conductivity sensor: 1.0cm-1, cable length 5m Double stage reverse osmosis system ①Collection point of input signal Water level of raw water tank, for checking with or without water Low pressure switch of first stage (before the first-stage high pressure pump) High pressure switch of first stage (after the first-stage high pressure pump) Low water level of mid tank High water level of mid tank (if no mid tank, high water level terminal is free, low water level can be replaced by low pressure switch) High pressure switch of second stage (after the second-stage high pressure pump) High water level of second-stage pure water tank (checking of water full) Communication switch of pretreatment (when pretreatment is working, the system is standby. ②Controlling point of output Raw water pump Inlet valve High pressure pump of first stage Flushing valve Over-limit discharge valve of first stage conductivity High pressure pump of second stage Over-limit discharge valve of second stage Relay of alarm (could be connected audible and visual alarm) ③ Measure collection point Raw water conductivity collection, one stage production water conductivity collection, two stage production water conductivity collection, temperature collection ④Conductivity measurement Raw water conductivity : 0~2000μS/cm; Conductivity of first-stage reverse osmosis :0~200μS/cm; Conductivity of second-stage reverse osmosis :0~20μS/cm Temperature test: 0-60℃ Conductivity sensor: 1.0cm-1, cable length 5m RO System Application