Professional China Orp Transmitter - Online ORP transmitter with sensor – JIRS

Code: BSQ-ORP-2019 General introduction EC/ER/pH/ORP-2019 series transmitter mainly used for the water quality monitor sensor signal output, by 4-20mA, RS485 or TTL, the sensor output weak signal is enlarged to transmit, can be convenient for PLC, configuration software and SCM to communicate by adopting standard communication protocol MODBUS protocol. EC/ER/pH/ORP series transmitter is widely used in metallurgy manufacturing, power, light industry, textile, water treatment equipment, water pipe network and the scientific research and other industrial sectors. Transmitter series introduction Note: A module of the transmitter can only be equipped with one sensor, EC/ER is a module, and PH / ORP is a module. ①: EC conductivity transmitter; range: 0 ~ 4000us / cm, 0-10/20/200mS ②: ER resistivity transmitter; range: 0 ~ 18.2MΩ ③: pH transmitter; range: 0 ~ 14.00 pH ④: ORP redox potential transmitter; range: -2000 ~ + 2000mV Transmitter series technique specification

No.

Range

Matched sensor

Accuracy

Connection

1

0.1~18.25MΩ

0.05~10.00uS)

1:316L S.S. plug into 0.01 sensor

2:Quick install 0.02 sensor;

2 %FS

1/2″NPT

1/4”Quick install

2

0.1~200.0uS

316L S.S. plug-into 0.1 sensor

 

1/2″NPT)

3

0.5~2000uS(standard)

ABS1.0 Pt. Black sensor(standard)

316L S.S. plug into 1.0 sensor

1.5% FS

1/2″NPT

 

4

2~4000uS

ABS1.0 Pt. Black sensor(standard)

316L S.S. plug into 1.0 sensor

1.5% FS

1/2″NPT

 

5

0.5~10mS

ABS1.0 Pt. Black sensor(standard)

316L S.S. plug into 1.0 sensor

3 % FS

1/2″NPT

 

6

0.5~20mS

1:316LS.S. plug into10.0 (standard)

2:PTFE+Titanium alloy 10.0 sensor

1.5 % FS

1/2″NPT

3/4″NPT

7

0.5~100mS

1:316LS.S. plug into10.0 (standard)

2:PTFE+Titanium alloy 10.0 sensor

2 % FS

1/2″NPT

3/4″NPT

8

0.5~200mS

PTFE+Titanium alloy 10.0 sensor

2 % FS

3/4″NPT

ORP- ORP(Redox) transmitter technique specification Measuring range: -2000~+2000mV Accuracy:1.0 %(FS) Stability: ±2×10-3FS/24h Sensor: online ORP sensor Sensor threaded size: 3/4″ BSP Cable length: standard length is 5m, Measured media temperature:0~100℃ 4.6 Other common technique specification Output current: 4~20mA, isolated / Optional:1-5V /2-10V; Relay output: High/Low limit relay alarm output, Contact point current 24V/3A, 220V/2A ( Passive dry contact) Power: DC12V-28V, 24V(Current <=0.1A), Environmental conditions: Working temperature:0~50℃, Relative humidity: ≤ 85%RH, Overall dimension: 122×72×45mm(L x W x H), Installation mode: Cabinet rail installation